1. Optimized for continuous operation at +37 °C, +25 °C and +10 °C, perfect for incubation at +15~+37 °C
2. Silent long shaft circulating fan for safety and uniform temperature distribution
3. SUS plate-type evaporator, frost-free reliable and efficient operation guaranteed
4. Choose between power-on modes of standby and auto-restart after power failure
5. Automatic defrosting capibility
6. Absolute temperature calibration (ATC) , units of Celsius and Fahrenheit temperature;
7. Timer for auto start-up or shut-down, temperature program up to 6 segments and 99 cycles
Model
UXP8111-IR150
Temperature Range
°C (°F)
4 ~ 65 (39.2 ~ 149.0)
Temperature Stability
±°C (°F)
0.2 (0.4)
Temperature Uniformity
2.0 (3.6)
ACC Temperature
40 (104)
Temperature Programming
6 segments×99h59min, 99 cycles
Timer
Timers for automatic start-up and automatic shut-down
Safety
Temperature sensor open/short cut off and alarm,
Independent STB cutoff and warning, door-open alarm
High-temperature cut off and low temperature alarm
Utility Function
Standby or auto-restart after power failure
Absolute temperature calibration, operator light
EMC for USA and Canada
Class A (for operation only on networks without connected domestic areas)
Duty Cycle
Continuous
Installation Conditions
Indoor use, and altitude: 2,000 meters
Ambient Temperature Range: 16 °C to 32 °C (class N)
Humidity: 75% RH at or below 32 °C
Mains supply fluctuations: Rated Voltage ±10%
Installation category: II **, Pollution Degree: 2 ***, Class of Equipment: I
Interior Material
SUS 430 stainless steel coated white
Housing Materials
SPCC steel with powder coating
Observation Window
IR models only
Compressor
W
185
Refrigerant
HFC134a
Heater Wattage
450
Effective Capacity
L (cf)
150 (5.30)
Interior Size (WDH)
mm (in)
550×450×615 (21.6×17.8×24)
Overall Dimensions (WDH)****
705×620×1090 (27.8×24.4×42.9)
Shelves*****
EA
2/5
Packing Size (WDH)
790×830×1320 (31.1×32.7×52.0)
Net Weight
Kg (lbs)
96 (211.6)
Gross Weight
114 (251.3)
Voltage and Frequency
115V~, 60Hz
Current Draw
A
8.5
* Measured under 20 °C ambient conditions, higher ambient may degrade the minimum temperature and cooling capacity.
** Installation category (overvoltage category) defines the level of transient overvoltage which the equipment is designed to withstand safely. It depends on the nature of the electricity supply and its overvoltage protection means. For example, in CAT II which is the category used for equipment in installations supplied from a supply comparable to public mains such as hospital and research laboratories and most industrial laboratories, the expected transient overvoltage is 250 V for a 230 V supply and150 V for a 115 V supply.
*** Pollution degree describes the amount of conductive pollution present in the operating environment. Pollution degree 2 assumes that normally only non-conductive pollution such as dust occurs with exception of occasional conductivity caused by condensation.
**** Maximum shelf and unit capacity is based on mechanical capabilities. Note that with heavy load the heat-up/cool-down time of the unit will increase, andt emperature performance might be impacted. A load below 30% of max. capacity, with even distribution in the chamber will provide optimal conditions.
*****Including feet / caster